Poor measurement performance with PH10 system
The PH10 system is giving poor measurement performance.
Description
Possible Cause
Solution
Loose head mounting
Ensure all mounting screws are tight and mounting to the CMM is secure.
Probe incorrectly installed
Remove probe and refit.
Force applied to head during lock up
Unlock and relock PH10.
Incorrect lock up position or position not qualified
Reposition head correctly. Check qualification information.