Home-CMM probes, software and retrofits-CMM support-CMM knowledgebase-3-axis systems-Scanning probe systems-SP25M-SP25M user's guide-Using the FCR25 and FCR25 TC

Navigation

CMM support

  • CMM knowledgebase
  • 3-axis systems
  • Scanning probe systems
  • SP25M
  • SP25M user's guide
  • General information
  • Product compliance
  • International safety instructions
  • General safety recommendations
  • Introduction
  • Design principles of the SP25M system
  • System components overview
  • Probe system components
  • FCR25 flexible change rack system
  • FCR25 TC temperature controlled flexible change rack
  • SP25M specification
  • Dimensions
  • Installation
  • Calibration
  • Operation
  • Technical terms
  • Using the FCR25 and FCR25 TC
  • FCR25 TC warm up time
  • Establishing a docking position for SM25 and TM25-20 modules
  • Establishing a docking position for SH25 stylus holders
  • Establishing a docking position for TP20 modules
  • Pick up routines
  • Put down routines
  • Speed of motion during a change routine
  • SP25M straight stylus carrying capability and performance guidelines
  • Maintenance
  • Appendix 1 - International safety recommendations

Navigation

CMM support

  • CMM knowledgebase
  • 3-axis systems
  • Scanning probe systems
  • SP25M
  • SP25M user's guide
  • General information
  • Product compliance
  • International safety instructions
  • General safety recommendations
  • Introduction
  • Design principles of the SP25M system
  • System components overview
  • Probe system components
  • FCR25 flexible change rack system
  • FCR25 TC temperature controlled flexible change rack
  • SP25M specification
  • Dimensions
  • Installation
  • Calibration
  • Operation
  • Technical terms
  • Using the FCR25 and FCR25 TC
  • FCR25 TC warm up time
  • Establishing a docking position for SM25 and TM25-20 modules
  • Establishing a docking position for SH25 stylus holders
  • Establishing a docking position for TP20 modules
  • Pick up routines
  • Put down routines
  • Speed of motion during a change routine
  • SP25M straight stylus carrying capability and performance guidelines
  • Maintenance
  • Appendix 1 - International safety recommendations

Using the FCR25 and FCR25 TC

It is assumed that the FCR25 and or the FCR25 TC has been installed on the MRS rack system as described in the 'Mounting an FCR25 and FCR25 TC to an MRS rail system' pages of this document.

It is also assumed that all SP25M system components have been set up as described in the installation pages of this document. Please refer to the installation pages for clarification of the various datum positions used in this document.

NOTE: It is necessary to inhibit the probe signal through software during the change routine.

CMM support

  • Knowledgebase
  • Manuals and installation guide downloads
  • Software downloads

CMM probes, software and retrofits

  • Hardware
  • Software
  • Retrofit
  • Support and downloads
  • 5-axis technology